Transformer oil Temperature Measurement using Tungsten Filament as Sensor
Abstract
Full Text:
PDFReferences
Y. Jiang, S. Liu, L. Xiao, W. Li. Fiber Bragg grating sensors for temperature monitoring in oil-immersed transformers, In: 15th International Conference on Optical Communications and Networks (ICOCN). 2016, 1–3p.
C. Wei-gen, L. Jun, W. You-yuan, L. Liu-ming, Z. Jian-bao, Y. Yanfeng. The measuring method for internal temperature of power transformer based on fbg sensors, In: International Conference on High Voltage Engineering and Application. 2008, 672–6p.
Z. Mu, Z.D. Wang, Q. Liu. Measurements of dc resistivity of insulating oils, In: 2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE). 2016, 1–4p.
C. Thammarat, B. Suechoey, S. Tadsuan, V. Kinnares, S. Bunjongjit. An analysis of temperature of oil-immersed transformer under non-linear load, In: International Conference on Power System Technology, PowerCon 2004. Vol. 1, 2004, 517–21p.
D.C. Agrawal, H.S. Leff, V.J. Menon. Efficiency and efficacy of incandescent lamps Am. J. Phys. 64, pp. 649–54p
H.S. Leff. Illuminating physics with light bulbs, Phys Teach. 1990; 28: 30–5p.
I.R. Edmonds. Stephan–Boltzmann law in the laboratory, Am J Phys. 1968; 36: 845–6p.
V.J. Menon, D.C. Agrawal. Switching time of a 100 Watt bulb, Phys Educ. 1999; 34: 34–6p.
D.C. Agrawal, V.J. Menon. Lifetime and temperature of incandescent lamps, Phys Educ. 1998; 33: 55–8p.
B.S.N. Prasad, R. Mascarenhas. A laboratory experiment on the application of Stefan’s Law to tungsten filament electric lamps, Am J Phys. 1978; 46: 420–3p.
DOI: https://doi.org/10.37628/ijemd.v3i2.610
Refbacks
- There are currently no refbacks.